Kantech EntraPass software and KT access controller family

Complete project delivery • Carolinas

360 Technology Group delivers Kantech KT-1, KT-2, KT-4 and KT-400: Wiring, Pricing and Installer Guide as an installed and supported solution. Our scope can include product sourcing and resale, engineering, installation, programming, commissioning, repair, lifecycle maintenance, system expansion and post-project support in North and South Carolina.

  • Equipment & Licensing
  • Engineering & Installation
  • Programming & Commissioning
  • Repair & Maintenance
  • Ongoing Support

New installation: For new work, we can coordinate the bill of materials, field installation, configuration, testing and turnover.

Existing system: For existing systems, we can troubleshoot faults, repair or replace components, maintain and modernize the deployment.

Authorized dealer · Certified installers · Charlotte, NC headquarters

360 Technology Group is an authorized Kantech dealer and certified installer

We have been selling, installing, programming and servicing Kantech systems across North and South Carolina since 2018 — more than 8 years. Our scope covers Kantech EntraPass software, KT-1, KT-2, KT-4 and KT-400 controllers, ioSmart readers and credentials.

  • Authorized Kantech dealer — we quote and supply genuine Kantech equipment, licensing and subscriptions.
  • Certified Kantech installers — our technicians install, wire, program, commission and document the system.
  • Repair and takeover — we service, troubleshoot, expand and take over existing Kantech installations we did not originally install.
  • 24/7 emergency service — on-call service technicians for emergency repairs, plus scheduled preventive maintenance.

We cover every city in North Carolina and South Carolina from our Charlotte headquarters. Request a quote or service call Call 704-726-4254

Installation, service, maintenance and support

Kantech KT-1, KT-2, KT-4 and KT-400: Wiring, Pricing and Installer Guide

Kantech controller selection should follow door count, EntraPass architecture, reader protocol, I/O, enclosure/power and expansion requirements. The controller is only one part of a code-compliant opening that includes lock, egress, monitoring and life-safety interfaces.

We install, configure, service, maintain and support Kantech products and software. Our work includes site surveys, system design, authorized product procurement, commissioning, training, troubleshooting, repair and lifecycle planning.

Kantech EntraPass software and KT access controller family

KT controllers and door hardware: what owners and buyers should evaluate

KT-1 and KT-2

Plan compact one- or two-door deployments by exact model, network path, power, enclosure, reader protocol, inputs/outputs and expansion. Confirm standalone versus EntraPass management requirements.

KT-4 and KT-400

Use multi-door controllers where centralized wiring and expansion fit the facility. Verify controller capacity, modules, communication, reader interfaces, memory, cabinet power and battery calculations.

ioSmart readers and credentials

Choose OSDP Secure Channel where supported and commissioned end to end. Define supported credential technologies, keypad, mobile or smart-card requirements and migration from legacy Wiegand.

Scope the complete system

Planning area What to verify
Installed price Controllers/modules, enclosures, power/UPS, readers, credentials, locks, REX/DPS, cable/pathway, network, licenses, labor and training.
Capacity and topology Doors/readers, cardholders/events, downstream modules, communication method, server/gateway, elevator/I/O and expansion reserve.
Electrical and life safety Lock current and voltage, battery/load calculation, fire release, egress, grounding/surge, supervised inputs and accessible operation.
Commissioning Addressing, firmware, encryption/protocol, time, schedules, alarms, offline behavior, event reporting, backup and as-built documentation.

Installation, upgrade and acceptance workflow

  1. Survey every opening and document door construction, handing, egress, fire-rating, locking hardware, power, pathways, network and accessibility requirements.
  2. Inventory the exact software edition, licenses, controllers, readers, credentials, integrations and current firmware before proposing additions or migration.
  3. Build a model-specific bill of materials and coordinate electrical, network, life-safety and door-hardware responsibilities before installation.
  4. Configure roles, schedules, holidays, credential workflows, alarms, integrations, backups and administrator recovery using least-privilege practices.
  5. Commission authorized, denied, forced, held, request-to-exit, fire-release, network-loss and power-loss behavior at every affected opening.
  6. Deliver as-builts, device and version records, administrator training, warranty information and a preventive-maintenance plan.

Kantech installation, maintenance, service and support

We supply, install, wire, program, commission, maintain and repair supported Kantech KT controllers, ioSmart readers, credentials, power supplies and door hardware, together with EntraPass software and database support.

Discuss a Kantech project or service call

Reviewed against current Kantech KT-controller, ioSmart, EntraPass, installation and support resources on July 19, 2026.