Authorized dealer · Certified installers · Charlotte, NC headquarters
360 Technology Group is an authorized Camden Door Controls dealer and certified installer
We have been selling, installing, programming and servicing Camden Door Controls systems across North and South Carolina since 2018 — more than 8 years. Our scope covers Camden touchless switches, restroom controls, electric strikes, magnetic locks, specialty locks and wireless control systems.
- Authorized Camden Door Controls dealer — we quote and supply genuine Camden Door Controls equipment, licensing and subscriptions.
- Certified Camden Door Controls installers — our technicians install, wire, program, commission and document the system.
- Repair and takeover — we service, troubleshoot, expand and take over existing Camden Door Controls installations we did not originally install.
- 24/7 emergency service — on-call service technicians for emergency repairs, plus scheduled preventive maintenance.
We cover every city in North Carolina and South Carolina from our Charlotte headquarters. Request a quote or service call Call 704-726-4254
Installation, service, maintenance and support
Camden Touchless Switches, Restroom Controls, Door Hardware Pricing and Installer Guide
Accessible automatic-door and restroom systems combine activation, locking, position sensing, annunciation, operator control and emergency behavior. The small devices must be engineered as a complete sequence so users receive clear, safe and reliable operation.
We install, configure, service, maintain and support Camden Controls products and systems. Work can include survey, engineering, procurement, field installation, software setup, commissioning, troubleshooting, repair, upgrades, administrator training and lifecycle planning.

Accessible door activation and control sequences: decisions before procurement
Touchless and push-plate activation
Select faceplate, graphics, illumination, detection range, relay output, weather/vandal resistance, wireless option, bollard/enclosure and manual override by user workflow.
Barrier-free restroom controls
Coordinate inside/outside activation, push-to-lock, door position, electric locking, occupancy/annunciation, operator sequencing and emergency override for one- or two-door layouts.
Emergency call and delayed egress
Define initiation, local annunciation, reset, supervision, backup power and response; separately document delayed-egress listing, nuisance control, fire release and user instructions.
Scope the complete installed system
| Planning area | What to verify |
|---|---|
| Installed price | Switches/plates, relay/controller, strike or maglock, contacts, annunciators, operator interface, power/battery, wire/pathway, signage and labor. |
| Sequence | Door closed/open, available/occupied, push-to-open/lock, REX, emergency release, fire alarm, power loss, operator timing and reset. |
| Mounting and environment | Height/reach, approach, wall/box/bollard, weather, vandal risk, cleaning, illumination, graphics and accessible alternatives. |
| Maintenance | Functional sequence test, sensor range, plate/graphics, door alignment, latch, contacts, relays, battery, emergency call and records. |
Installation, upgrade and acceptance workflow
- Survey the opening, handing, frame and door material, lockset, latch geometry, preload, closer, operator, egress, fire rating, accessibility and environmental exposure.
- Select the exact strike, maglock, switch, relay, sensor, power supply and mounting accessory using current manufacturer selection tools and documents.
- Produce a point-to-point sequence showing access-control, operator, fire-alarm, REX, door-position, annunciation and emergency-release behavior.
- Install hardware without weakening listed assemblies; align the door, route protected wiring, label conductors and configure timing and logic.
- Test normal access, denied access, free egress, fire release, power loss, operator sequencing, door-held conditions and every accessible-use workflow.
- Document models, settings, wiring, approvals used, test results, spare components and inspection/maintenance intervals.
Common buyer and administrator questions
What is included in a Camden restroom kit?
Current CX-WC configurations can combine control relay, activation switches, annunciation, door contact and electric strike, with options varying by exact kit.
Can touchless switches work with automatic doors?
Yes, when the relay, operator input, lock release and safety sequence are engineered and tested together. Confirm contact ratings and timing.
Does Camden publish a price list?
Camden publishes a current catalog/price list. Installed cost also depends on the existing door/operator, wiring, power, locking, code review and commissioning.
Do you maintain accessible door controls?
Yes. Maintenance can include switch/sensor tests, sequence verification, door/lock alignment, relays, power, annunciation and emergency operation.
Official manufacturer resources
Use manufacturer-controlled pages for current manuals, software, firmware, compatibility and release information. We link to those portals and do not host firmware locally.
Camden Controls installation, maintenance, service and support
We design, install, integrate, test, repair and maintain supported Camden touchless/push-plate switches, restroom and emergency-call controls, strikes, maglocks, relays, power and automatic-door interfaces.